2610kWh / 1250kW Commercial And Industrial Energy Storage System

2610kWh / 1250kW Commercial And Industrial Energy Storage System

2610kWh / 1250kW Commercial And Industrial Energy Storage System

Commercial & Industrial Energy Storage

Home / Products / 2610kWh / 1250kW Commercial And Industrial Energy Storage System

TAOYAN’s 2610kWh / 1250kW Commercial & Industrial (C&I) Energy Storage System delivers large-scale, liquid-cooled LFP battery storage in a standard ISO container for industrial parks, commercial complexes and utility-scale projects. With 2610kWh capacity, an 832V battery architecture and a 1250kW PCS, it enables peak shaving, demand response and microgrid operation. Explore the full C&I energy storage lineup →

Product Overview

2610kWh / 1250kW Commercial And Industrial Energy Storage System 2610kWh / 1250kW Commercial And Industrial Energy Storage System 2610kWh / 1250kW Commercial And Industrial Energy Storage System 2610kWh / 1250kW Commercial And Industrial Energy Storage System 2610kWh / 1250kW Commercial And Industrial Energy Storage System
2610kWh / 1250kW Commercial And Industrial Energy Storage System
Cell Type314Ah-LEP
Capacity2610kWh
Configuration260S 1P
Nominal Voltage832.0V
Operating voltage range915.2-748.8V
Operating Temperature Range-25°C to 55°C
Cooling MethodLiquid cooling
Cycle Life≥8000 cycles
Protection LevelIP54
Operating Altitude≤4000m
Dimensions (W x D x H) mm6058*2438*2440
Weight23073KG
  • TY-2610kW-BESS
  • TAOYAN
  • TY2610-2026

Download: 2610 kWh Energy Storage System Specifications.pdf

Battery Module (1P52S Cell)

Battery Module
Capacity52.2KWH
Configuration52S1P
Nominal Voltage166.4V
Cell Capacity314Ah
Dimension442×1050×235 mm
Weight300 KG

Inverter Specifications (MW-Level)

Inverter
AC Rated output power1250KW
AC Maximum output power1300KW
Rated voltage690.0V
Rated frequency50/60Hz
Maximum PV input voltage1000.0V
MPPT operating voltage range250V-850V
MPPT full load voltage range450V-850V

TY-EMS Energy Management System

The TY-EMS (Energy Management System) is a highly integrated local monitoring and energy-management unit. Running Linux on a 64 GB / 4 GB-RAM board, it communicates with PCS, BMS, liquid-cooling units and smart meters via Modbus RTU/TCP, and syncs to a cloud Java backend for remote policy distribution and multi-site coordination — the intelligent brain behind every TAOYAN C&I storage system.

Multi-Device Access

Connects PCS, BMS, liquid cooling and meters with flexible quantities.

Real-Time Monitoring

Live dashboard with total power, SOC and 24-hour trend.

Battery Protection

SOC / voltage / temperature thresholds with auto cutoff.

Power Limitation

Dynamic setpoints per transformer and grid limits.

Charge / Discharge Strategy

Up to 10 time-of-use periods for peak shaving.

Local GPIO & Remote Mgmt

On-site HMI plus cloud backend with role permissions.

Features

Fire Protection System

Wiring Methods

After-sales Service

Typical Applications

Peak Shaving & Valley Filling

Charge during off-peak hours and discharge at peak tariff, cutting electricity bills for factories and commercial complexes.

Stable Microgrid Operation

Coordinate PV, storage and diesel with seamless island / grid-connected switching for critical loads.

Solar-Storage-Charging

Prioritize PV consumption, store excess energy and supply stable power to EV charging piles.

Backup Power Supply

On mains interruption the system switches to battery discharge, keeping core equipment running.

Frequently Asked Questions

1. What are the main applications for the 2610kWh / 1250kW system?

This MW-level system is designed for large-scale industrial parks, utility-scale peak shaving, and high-capacity renewable energy integration where massive energy buffer is required.

2. How does the 690V AC output benefit large industrial users?

The 690V rated voltage reduces current during high-power transmission, leading to lower line losses and significantly reducing the cost of AC cabling for large facilities.

3. Is the thermal management sufficient for such a large battery bank?

Yes. Our advanced liquid cooling system ensures that all 314Ah cells within the 2610kWh container operate within an optimal temperature range (deviation <3°C), even during high-power 1250kW discharge.

4. Can this system participate in grid frequency regulation?

With its high-power 1250kW inverter and rapid response time, the system is fully capable of participating in ancillary grid services like frequency response and voltage regulation.

5. What level of safety protection is integrated?

The system features a multi-tiered safety architecture, including per-cell monitoring, module-level aerosol suppression, and container-level fire protection systems.

6. How is the 2610kWh system transported and installed?

It is housed in a standard ISO-compliant container. The system is "plug-and-play" ready, requiring only AC connection and communication commissioning upon arrival at the site.

7. How does the EMS handle complex energy trading?

Our smart EMS supports AI-driven strategies for arbitrage, demand response, and solar forecasting, maximizing the ROI of your 2.6MWh investment.

☎+86-134-2346-1319✉jenny@dgtaoyan.com📱WhatsApp: +86-134-2346-1319▲回到顶部