Solution 2610KWH-1250KW
Description du projet
This project delivers a 2.61MWh / 1.25MW grid-connected battery energy storage system (BESS) built around an advanced liquid-cooled lithium iron phosphate (LFP) architecture. The system is engineered for industrial-scale peak shaving, load shifting, and frequency regulation, enabling facilities to dramatically reduce electricity costs through intelligent energy time-of-use arbitrage.
The solution is housed in a single 20-foot ISO containerized unit featuring a dual-chamber design: a battery chamber with ten (10) strings of liquid-cooled LFP battery clusters (832V / 314Ah each), and a power conversion chamber housing a modular 1250kW PCS composed of ten parallel 125kW inverter modules. The integrated liquid thermal management system maintains optimal cell temperatures across a wide -25°C to 55°C operating range, delivering superior cycle life and round-trip efficiency compared to air-cooled alternatives.
Capacité énergétique totale
Puissance de sortie nominale
Conteneur 20 pieds
Rendement PCS
Chimie de la cellule
Indice de protection
🔌 Innovation clé : BESS containerisé tout-en-un refroidi par liquide
This solution packs 2.61MWh of liquid-cooled LFP storage plus a 1250kW PCS into a single 20ft container. The liquid cooling system uses an integrated die-cast cold plate design that merges the cooling plate with the battery module enclosure, eliminating coolant leakage risk while achieving IP67 protection at the module level. Ten battery clusters (each 832V / 261.248kWh) connect via a centralized DC bus to ten 125kW PCS modules operating in parallel, delivering up to 1300kW peak output to the 400V AC grid with four-quadrant control and power factor >0.99. The result: industry-leading energy density, extended cycle life (≥8000 cycles), and rapid deployment with minimal site preparation.
- LFP refroidi par liquide Battery System: Ten clusters of 832V / 314Ah LFP cells (2610 kWh total) using 3.2V prismatic cells with integrated die-cast liquid cooling plates. Each module (52S1P, 166.4V / 52.25kWh) achieves IP67 protection. Cycle life ≥8000 cycles at 80% DOD.
- Modular PCS Architecture: Ten × 125kW PCS modules (EPCS1250-AS) operate in parallel via centralized DC bus, delivering 1250kW rated / 1300kW maximum output. Four-quadrant active/reactive control, power factor >0.99, THD <3%.
- Advanced Thermal Management: Dual-circuit liquid cooling (refrigeration + heating) maintains battery temperature within optimal range. PTC heater ensures reliable charging in cold environments down to -25°C. Compressor-based refrigeration handles high-rate discharge heat rejection.
- Integrated Safety Systems: Multi-layer protection including three-level BMS (BMU/BCMU/BAMS), heptafluoropropane gas fire suppression with <8s fill time, smoke/heat detection, emergency lighting, and access control interlock. IP54 container protection.
- Rapid Deployment: Single-container design eliminates need for dedicated battery building. Factory-tested complete unit transported to site, installed on concrete plinth with only grid connection required. 25-tonne total weight.
Images du projet



Spécifications du système de batteries
| Paramètres du pack de batteries | |
|---|---|
| Type de cellule | LFP – 314Ah prismatique |
| Capacité totale | 2,610 kWh (2612.48 kWh) |
| Configuration de la batterie | 10P260S (10 clusters × 260S) |
| Tension nominale | 832 V DC |
| Plage de tension | 748 V – 915 V DC |
| Température de fonctionnement | -25°C to 55°C |
| Méthode de refroidissement | Refroidi par liquide (plaque froide moulée sous pression intégrée) |
| Durée de vie en cycles | ≥ 8,000 cycles @ 80% DOD |
| Indice de protection | IP54 (Container) / IP67 (Module) |
| Altitude maximale | ≤ 4,000 m |
| Dimensions (L×P×H) | 6,058 × 2,438 × 2,896 mm (20ft container) |
| Poids total | ≈ 25 Tonnes |
| Spécifications du module de batterie | |
| Capacité du module | 52.25 kWh |
| Configuration du module | 1P52S (52 cells in series, 1 parallel) |
| Tension nominale | 166.4 V DC |
| Capacité de la cellule | 314 Ah |
| Dimensions du module (L×P×H) | 810 × 1,150 ×245 mm |
| Poids du module | 360 kg |
| Spécifications du cluster de batteries | |
| Capacité du cluster | 261.248 kWh |
| Configuration du cluster | 5 modules × 1P52S + High-Voltage Box |
| Tension nominale | 832 V DC |
| Plage de tension de fonctionnement | 728 V – 936 V DC |
| Nombre de clusters | 10 clusters per container |
Spécifications onduleur et PCS
| Paramètres PCS (EPCS1250-AS) | |
|---|---|
| Type d’onduleur | Raccordé au réseau (On-Grid) |
| Puissance de sortie nominale | 1,250 kW |
| Puissance de sortie maximale | 1,300 kW |
| Plage de tension DC | 650 V – 950 V DC |
| Courant DC maximal | 1,630 A (163 A × 10 strings) |
| Nombre de strings DC | 10 strings |
| Tension AC nominale | 400 V AC (3-phase 4-wire) |
| Plage de tension du réseau | 320 V – 450 V AC |
| Courant AC maximal | 1,590 A |
| Fréquence nominale | 50 / 60 Hz |
| Facteur de puissance | > 0.99 (at rated power) |
| Plage de facteur de puissance | -1 (leading) ~ 1 (lagging) |
| Distorsion harmonique totale | < 3% (at rated power) |
| Rendement maximal | 98% |
| Méthode de refroidissement | Refroidissement par ventilateur forcé |
| Niveau sonore | < 70 dB |
| Dimensions (L×P×H) | 1,600 × 1,000 × 2,400 mm |
| Weight | 750 kg (10 × 125kW modules) |
Spécifications conteneur et système de sécurité
| Aperçu du conteneur | |
|---|---|
| Type de conteneur | 20ft Standard ISO Container |
| Dimensions extérieures (L×P×H) | 6,058 × 2,438 × 2,896 mm |
| Poids total | ≈ 25 Tonnes |
| Agencement des compartiments | Double chambre : chambre batterie + chambre onduleur |
| Refroidissement de la chambre batterie | Système de refroidissement liquide (40kW de réfrigération + chauffage PTC) |
| Refroidissement de la chambre onduleur | Air forcé (refroidissement par ventilateur) |
| Indice de protection | IP54 (Container) / IP67 (Battery Module) |
| Système de suppression d’incendie | |
| Type d’agent | Gaz heptafluoropropane (HFC-227ea) + extinction par poudre de secours |
| Temps de remplissage | < 8 seconds (full battery chamber coverage) |
| Détection | Capteurs de fumée + capteurs de chaleur + alarme acoustique/optique |
| Interverrouillage de sécurité | Arrêt automatique du système lors de la détection ; indicateur de libération de gaz |
| BMS (système de gestion de batterie) | |
| Architecture | 3 niveaux : BMU (module) → BCMU (cluster) → BAMS (réseau) |
| Précision d’estimation SOC | ≤ 5% |
| Communication | CAN bus + RS485 + Ethernet |
| Fonctions clés | Surveillance en temps réel, équilibrage des cellules (passif), protection surtension/sous-tension/surtension de courant/température, gestion thermique, journalisation d’événements (stockage 128 Mo) |
| EMS (système de gestion de l’énergie) | |
| Fonctions | Surveillance en temps réel, planification d’écrêtement, optimisation TOU, dispatch à distance, alarme de défaut, rapports, analyse de courbes |
| Prise en charge des protocoles | MODBUS RTU/TCP |
| Interface utilisateur | IHM tactile + connectivité SCADA à distance |
Système de gestion de l’énergie TAOYAN (EMS)
This project is equipped with TAOYAN’s self-developed Gestion de l’énergie System (EMS) — a comprehensive monitoring, control, and revenue optimization platform designed specifically for industrial BESS deployments. The EMS provides real-time visibility into every aspect of the energy storage system, from individual cell-level data to grid-wide economic performance.
Tableau de bord de fusion EMS — topologie système en temps réel, état des unités, statistiques de revenus & courbes de puissance
Capacités principales
- System Topology Visualization: Interactive single-line diagram showing real-time power flow between Grid, Combiner, Battery Units, and Factory Load — with live voltage, current, and power readings at each node.
- Unit-Level Surveillance: Individual status for each battery cabinet — SoC %, charge/discharge power (kW), voltage (V), current (A), temperature, and health status with normal/warning/fault indicators.
- PCS Power & SoC Suivi: 24-hour rolling charts for PCS output power and battery State of Charge, enabling operators to verify scheduling execution and identify anomalies.
- Batch Contrôle Panel: One-click operation mode switching between Manual Charge, Manual Discharge, All-weather Auto, and Scheduled modes — with immediate effect confirmation.
- Revenu Analytics: Daily/monthly/yearly income tracking broken down by tariff period (Sharp / Peak / Flat / Valley) with profit calculation based on Taiwan Power Company (Taipower) rate schedules.
- Charge/Discharge Statistics: Comprehensive kWh accounting with daily bar-chart comparison, cumulative totals, and exportable reports for financial reconciliation.
Courbes de puissance PCS, suivi SoC, panneau de contrôle par lots & schéma de câblage en temps réel

Graphique de comparaison de charge/décharge quotidienne avec détail des revenus par période